D-60A CH1

DC output voltage:5V

Rated output current:4A

DC Output power:56W

Model
Specification
D-60AD-60B
CH1CH2CH1CH2
DC output voltage5V12V5V24V
Output voltage range(Note:2)±2%±6%±2%±5%
Rated output current4A3A3A1.8A
Output current range(Note:2)0.3-6A0.2-4A0.3-6A0.2-2.2A
Wave and noise(Note:3)75mVp-p150mVp-p75mVp-p150mVp-p
Inlet stability(Note:4)±0.5%±1%±0.5%±0.5%
Load stability(Note:5)±0.5%±4%±0.5%±4%
DC Output power56W58W
Efficiency73%76%
Adjustable range for DC voltageCH1; +10, -5%CH1; +10, -5%
AC input voltage range85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC
Input current2A/115V 1A/230V
AC Inrush currentCole-start current 308A/115V 60A/230V
Leakage current<1mA/240VAC
Overload protection105%~135% Type: Cut off output Reset: auto recovery
Over-voltage protectionCH1: 5.75~6.75V
High-temperature protection……………………
Temperature coefficient±0.03%/℃(0~50℃)
Setup,rise,hold up time800ms, 50ms, 10ms/115VAC 300ms,50ms,80ms/230VAC
Vibration10~500Hz, 2G 10min,/1cycle, period for 60min, Each axes
Withstand voltageInput and output internal: 1.5KvAC, Input and enclosure: 1.5KvAC,
Output and enclosure: 0.5KvAC
Isolation resistanceInput and output internal: Input and enclosure,
Output and enclosure: 500VDC/100MΩ
Working temperature and humidity-10℃~+60℃(Refer to output derating curve),20%~90%RH
Stoerall dimension-20℃~+85℃,10%~95%RH
Overall dimension159×97×38mm
weight0.55Kgs
safety standardsMeet UL 1012 requirement (Not apply for the mark)
EMC standards……………………