DC output voltage:24V
Rated output current:16.6A
DC Output power:400W
Model Specification | LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 | |
---|---|---|---|---|---|---|
Output | DC output voltage | 12V | 15V | 24V | 36V | 48V |
Rated output current | 12.5A | 10A | 6.5A | 4.3A | 3.3A | |
Output current range(Note:2) | 0-12.5A | 0-10A | 0-6.5A | 0-4.3A | 0-3.3A | |
DC Output power | 150W | 150W | 150W | 150W | 150W | |
Wave and noise(Note:3) | 150mVP-P | 150mVP-P | 200mVP-P | 200mVP-P | 200mVP-P | |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage accuracy | ±2% | ±2% | ±2% | ±2% | ±2% | |
Inlet stability(Note:4) | ±1% | ±1% | ±1% | ±1% | ±1% | |
Load stability(Note:5) | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | |
Setup,rise,hold up time | 1300ms, 50ms/230VAC,1300ms, 50ms//115VAC(full load) | |||||
Input | AC input voltage range and frequency | 90~132VAC/170-264VAC ;47~63Hz;240~370VDC | ||||
Efficiency | 1 . 1 % | 88% | 1 . 1 % | 1 . 1 % | 89% | |
Input current | 3A/115VAC;1.7A/230V | |||||
AC Inrush current | Cole-start current: 30A/115V,60A/230V | |||||
Leakage current | <0.75mA/240VAC | |||||
Protection | Overload protection | 105%~150% Type: Cut off output Reset: auto recovery | ||||
Over-voltage protection | 13.8-16.2V | 18-21V | 28.8-33.6V | 41.4-46.8V | 55.2-64.8V | |
Environment | Working temperature and humidity | -20℃~+70℃(Refer to output derating curve),20%~90%RH | ||||
Stoerall dimension | …………………… | |||||
Temperature coefficient | ±0.03%/℃(0-50℃) | |||||
Vibration | 10~500Hz, 2G 10min,/1cycle, period for 60min, Each axes | |||||
Standards | safety standards | Meet UL508,TUVEN60950-1 requirement (Not apply for the mark) | ||||
Withstand voltage | I/P-O/P:3KVAC,I/P-FG: 2KVAC,O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH | |||||
Others | MTBF standards | …………………… | ||||
Overall dimension | 159X97X30mm(W*H*D) | |||||
weight | 0.45Kgs |