SPECIFICATION
ModelMS-150-24
OUTPUTDC VOLTAGE24V
RATED CURRENT4.2A
CURRENT RANGE0 ~ 4.2A
RATED POWER100.8W
RIPPLE&NOISE(Max)120mVp-p
VOLTAGE ADJ.RANGE21.6 ~ 26.4V
VOLTAGE TOLERANCE±1.0%
LINE REGULATION±0.5%
LOAD REGULATION±1.0%
SETUP,RISE TIME200ms、100ms、30ms
HOLD UP TIME(Typ.)25ms/230VAC
INPUTVOLTAGE RANGE170~264VAC or120~370V
FREQUENCY RANGE47~63Hz
EFFICIENCY(Typ.)0.84
AC CURRENT(Typ.)0.8A/230
INRUSH CURRENT(Typ.)COLDSTART: 45A/230
LEAKAGE CURRENT<2.5mA/240VAC
PROTECTIONOVER
LOAD
115~ 135% ratedoutputpower
Protection type : Hiccuo mode,recovers automatically after fault condition is removed
OVER
VOLTAGE
28.8 ~ 33.6V
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
ENVIRONMENTWORKING TEMP-10 ~ +60°C (Referto“derating curve” )
WORKING HUMIDITY20~90%RH non-condensing
STORAGETEMP.,HUMIDITY-20 ~ +85°C, 10 ~ 95% RH
TEMP.COEFFICIENT0.03%/(0~50)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETYSAFETY STANDARDSCE,GB4943.1safety standard
WITHSTAND VOLTAGEI/P-O/P:1.5KVAC 1minute I/P-FG:1.5KVAC 1minute O/P-PG:0.5KVAC 1minute
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100MOhms/500VDC
EMC EMISSIONEN61000-3-2 2014/EN61000-3-3 2013
EMC IMMUNITYEN 55032:2015/EN55035:2017/60950-1
OTHERSMTBF327.9K hrs MIL-HDBK-217F(25°C)
DIMENSIONL199*W98*H38mm